Access Analyzer 11.6 Error: Data at the Root Level Is Invalid Line 3 Position 5
This article addresses the error message "Data at the root level is invalid" encountered in Netwrix Access Analyzer version 11.6, detailing its causes and resolutions.
This article addresses the error message "Data at the root level is invalid" encountered in Netwrix Access Analyzer version 11.6, detailing its causes and resolutions.
When the 2-FSAA Bulk Import job returns "SQL logic error unknown database strucmap.", the database structure map is likely corrupted. This article describes causes and provides two resolutions: resetting the hosts and repairing the SQL database.
Users other than the `admin` account cannot access Netwrix Access Analyzer (AIC) when the SQL database password is expired or incorrect; this article explains how to update the database password in the Configure Console.
Common applet errors encountered when running Exchange Metrics, SMARTLog, and FSAA queries in Access Analyzer, with causes and recommended resolutions. Includes guidance for WMI memory settings, firewall and port conflicts, and process termination.
Explains how to resolve the "Could not drop object ... because it is referenced by a foreign key constraint" error when running the SP_DropTables job by identifying and removing the blocking foreign key constraints.
Describes how to resolve the "Error getting scan database from execution host: One or more errors occurred" message when a file system scan using a proxy fails due to insufficient disk space by migrating the File System Proxy service to another drive.
When saving a scheduled task, Netwrix Access Analyzer may report a logon session error caused by a Local Security Policy that prevents storing passwords and credentials. This article explains the symptom, cause, and resolution.
Explains why Access Information Center and the SA_FSAA_Hosts table show a !REMOVED_<GUID> machine name after a host data removal job times out, and how to fix it.
Explains how to resolve the "Cannot create a file when that file already exists" (Error 183) when creating an SSL binding for Netwrix Access Analyzer Access Reports or Access Information Center by unbinding the prior certificate and binding a new one.
When opening the Netwrix Access Analyzer console, you may see "System Error. Code: 5. Access is denied." This article explains the cause and provides steps to resolve the issue by granting the required permissions to the %SAInstallDir% folder.
File System Scan can fail with a "connection attempt failed" error when the audited host is unreachable due to blocked ports. This article explains the cause and shows how to test and resolve connectivity on ports 8767 and 8766.
When using SSO for the Published Reports web console (port 8082), you may receive an HTTP 400 Bad Request (Request Header too long). This article explains the cause and how to adjust the IIS HTTP registry limits (`MaxFieldLength`, `MaxRequestBytes`) to resolve the issue.
Explains why a Netwrix Access Analyzer job fails with "Job connection profile is not available" and how to resolve it by selecting the default connection profile in job and job group settings.
Describes an error encountered when an Active Directory Inventory scan detects an access control list (ACL) that exceeds the allowed maximum size, and provides steps to prevent the scan from terminating.
This article addresses the error message "Object doesn't support property or method" encountered in the Netwrix Access Analyzer and provides steps to resolve it.
Describes how to resolve "Refused to connect" errors when accessing Web Reports by unbinding a conflicting reserved URL on the Netwrix Access Analyzer host.
You receive "Request for downloading published reports failed: Internal Server Error" when opening the Reporting web page or encounter a corrupted published report file in Netwrix Access Analyzer. This article explains the cause and provides step-by-step instructions to rebuild the Reports folder and republish reports.
When selecting Schedules or any Job you may see an "Error: Failed to initialize task" pop-up because a Windows Task Scheduler job references the Netwrix Auditor executable `StealthAUDIT.exe` but lacks required fields. Delete the failed task from Task Scheduler to resolve the error.
This article describes the "FAILED: the default schema name is incorrect" error that appears when you open or close Netwrix Access Analyzer and provides possible causes and resolutions to restore database access.
Describes how to resolve "Unable to find domain for member" errors in the Access Information Center (AIC) debug log when temporary access to shares fails to expire.
Explains why users are prompted for credentials in a Single Sign-On environment after upgrading to v11.6 and how to resolve it by registering Service Principal Names (SPNs) for the web server service account.
Explains the "Failed to create FSAdapter (80070002)" error in Netwrix Access Analyzer caused by an incompatibility with the Sensitive Data Discovery Add-On and how to resolve it by updating both components.
When exporting the AD Group Members View report as CSV, you may encounter a '(File not found error)' with 'Unable to log error to Access Analyzer: Object doesn't support property or method 'LogJSMessage'.' This article explains the cause and provides step-by-step resolution by enabling the interactive grid and CSV export option.
FSAA Tier 2 copy operations fail when the target or proxy server disk is full; free or add disk space to resolve the error.
This article explains how to troubleshoot the FSAA registry key error that occurs when an FSAA scan cannot open a registry key on Windows or NAS hosts.
This article explains the "Host is offline" error during a job run in Netwrix Access Analyzer and how to resolve it by disabling the Skip Hosts that do not respond to PING option.
This article explains how to manually enable debug logging in Netwrix Access Analyzer by editing the GlobalOptionsconfig.xml file and setting the LOGLEVEL value to 0 so you can access detailed application logs.
Explains symptoms, causes, and step-by-step resolutions for Netwrix Threat Prevention agents that stop processing or lose events during high event traffic, including log and policy tuning guidance.
Explains how to resolve the "Sequence contains more than one matching element." error in Netwrix Access Analyzer by removing duplicate entries from the report.xml file.
Opening the Schedules tab in Netwrix Access Analyzer 12.x fails with "Sequence contains more than one matching element" after an upgrade from 11.6. Remove the duplicated job folder from the Jobs directory to resolve it.
You see an "Unable to write to the specified folder" error when installing or uninstalling the FSAA Proxy Scanner or the Sensitive Data Discovery Add-on in Netwrix Access Analyzer. This article explains the cause and shows how to resolve the issue by verifying write permissions and disk space.