Skip to main content

Cannot Remove UI Configuration from Jobs Using PowerShell Data Collector Jobs with Parameters

Symptom​

In the Netwrix Access Analyzer (formerly Enterprise Auditor) Management Console, you cannot remove an unneeded output path in a job's configuration settings via the UI. When the path is removed, the option to save the setting appears disabled as shown below.

![Output path disabled in UI]./../0-images/servlet_image_b26ce25b201c.png)

Cause​

The current design of the Access Analyzer Management Console does not allow saving empty values for the UI configuration fields within the job configuration settings.

Resolution​

To remove the output path variable, use the PowerShell Data Collector wizard as a workaround:

  1. Open the job query in the Access Analyzer Management Console.

  2. Highlight the needed query and select Query Properties.

  3. In the Query Properties pop-up window, click Configure.

  4. Select the Edit Query option.

  5. Click the Parameters button on the right side of the Edit PowerShell Query Settings.

  6. Select the parameter to be cleared and click Edit.
    ![Edit parameter]./../0-images/servlet_image_dcd3919a2b21.png)

  7. Once the value box appears, delete the value and click OK.
    ![Delete value]./../0-images/servlet_image_df5aa01d204f.png)

  8. Complete the rest of the PowerShell Data Collector wizard by clicking Next and Finish.

  9. Click OK on the query properties box.

  10. Return to the job page and verify that the output path variable is empty.

NOTE: This workaround is temporary. A feature request has been submitted to allow saving empty values directly through the UI in a future release.