Skip to main content

Install & Configure Dell CEE

Dell CEE should be installed on a Windows or a Linux server. The Dell CEE software isn't a Netwrix product. Dell customers have a support account with Dell to access the download.

tip

Remember, the latest version is the recommended version of Dell CEE.

info

Install the Dell CEE package on the Windows server where the Activity Monitor agent will be deployed (recommended) or on any other Windows or Linux server.

Step 1 – Obtain the latest CEE install package from Dell and any additional license required for this component. It is recommended to use the most current version.

Step 2 – Follow the instructions in the Dell Using the Common Event Enabler on Windows Platforms guide to install and configure the CEE. The installation will add two services to the machine:

  • EMC Checker Service (Display Name: EMC CAVA)
  • EMC CEE Monitor (Display Name: EMC CEE Monitor)
info

The latest version of .NET Framework and Dell CEE is recommended to use with the asynchronous bulk delivery (VCAPS) feature.

See the CEE Debug Logs section for information on troubleshooting issues related to Dell CEE.

After Dell CEE installation is complete, connect Data Movers to the Dell CEE Server.

Configure Dell Registry Key Settings​

In some cases, install Dell CEE on a different Windows server than the one where the Activity Monitor activity agent is deployed. In those cases, manually set the Dell CEE registry key to forward events.

Step 1 – Open the Registry Editor (run regedit).

registryeditor

Step 2 – Navigate to following location:

HKEY_LOCAL_MACHINE\SOFTWARE\EMC\CEE\CEPP\AUDIT\Configuration

Step 3 – Right-click Enabled and select Modify. The Edit DWORD Value window opens.

Step 4 – In the Value data field, enter the value of 1. Click OK, and the Edit DWORD Value window closes.

Step 5 – Right-click EndPoint and select Modify. The Edit String window opens.

Step 6 – In the Value data field, enter the StealthAUDIT value with the IP Address for the Windows proxy server hosting the Activity Monitor activity agent. Use the following format:

StealthAUDIT@[IP ADDRESS]

Examples:

StealthAUDIT@192.168.30.15

Step 7 – Click OK. The Edit String window closes. Registry Editor can be closed.

services

Step 8 – Open Services (run services.msc). Start or Restart the EMC CEE Monitor service.

The Dell CEE registry key is now properly configured to forward event to the Activity Monitor activity agent.

Connect Data Movers to the Dell CEE Server​

The cepp.conf file contains information that is necessary to connect the Data Movers to the Dell CEE server. An administrator must create a configuration file which contains at least one event, one pool, and one server. All other parameters are optional. The cepp.conf file resides on the Data Mover.

Step 1 – Log into the Dell Celerra or VNX server with an administrator account. The administrative account should have a $ character in the terminal.

note

Don't use a # charter.

Step 2 – Create or retrieve the cepp.conf file.

If there isn't a cepp.conf file on the Data Movers, use a text editor to create a new blank file in the home directory named cepp.conf. The following is an example command if using the text editor 'vi' to create a new blank file:

$ vi cepp.conf

If a cepp.conf file already exists, retrieve it from the Data Movers for modification with the following command:

$ server_file [DATA_MOVER_NAME] -get cepp.conf cepp.conf

Step 3 – Configure the cepp.conf file. For information on the cepp.conf file, see the Dell Using the Common Event Enabler for Windows Platforms guide instructions on how to add parameters or edit the values or existing parameters.

note

Add the information to the file on one line or separate lines by using a space and a """ at the end of each line, except for the last line and the lines that contain global options: cifsserver, surveytime, ft, and msrpcuser.

Set the following parameters in the cepp.conf file for the Activity Monitor:

  • pool name=

    • Assign the name of the configuration container. This container is composed of the servers IP Address or FQDN where the Dell CEE is installed and where the list of events to be monitored is located. Name it as desired, but it must function as a pool name.
  • servers=

    • This should equal the IP Address or FQDN of the Windows server where the Dell CEE is installed. If several servers are specified, separate them with the vertical bar (|) or a colon (:).
  • postevents=

    • Include the following events (separated with the vertical bar): CloseModified|CloseUnmodified|CreateDir|CreateFile|DeleteDir|DeleteFile|RenameDir|RenameFile|SetAclDir|SetAclFile
    • To monitor "Directory Read/List" operations, append OpenDir to the list.
  • msrpcuser=

    • Specify the domain account that runs the Dell CEE Monitor and Dell CAVA services on the Windows server. This parameter ensures that events are sent only to the appropriate servers.

      All unspecified parameters use the default setting. For most configurations, the default setting is sufficient.

    Example cepp.conf file format:

msrpcuser=[DOMAIN\DOMAINUSER]

pool name=[POOL_NAME] \

*servers=[IP_ADDRESS1]|[IP_ADDRESS2]|... *

postevents=[EVENT1]|[EVENT2]|...

Example cepp.conf file format for the Activity Monitor:

msrpcuser=[DOMAIN\DOMAINUSER running CEE services]

pool name=[POOL_NAME for configuration container] \

*servers=[IP_ADDRESS where CEE is installed]|... *

postevents=[EVENT1]|[EVENT2]|...

Example of a completed cepp.conf file for the Activity Monitor:

msrpcuser=example\user1

pool name=pool \

*servers=192.168.30.15 *

postevents=CloseModified|CloseUnmodified|CreateDir|CreateFile|DeleteDir|DeleteFile|RenameDir|RenameFile|SetAclDir|SetAclFile

Step 4 – Move the cepp.conf file to the Data Movers root file system. Run the following command:

$ server_file [DATA_MOVER_NAME]-put cepp.conf cepp.conf

note

Each Data Mover which runs Celerra Event Publishing Agent (CEPA) must have a cepp.conf file, but each configuration file can specify different events.

Step 5 – (Perform this step only if using the msrpcuser parameter) Register the MSRPC user (see Step 3 for additional information on this parameter). Before starting CEPA for the first time, the administrator must issue the following command from the Control Station and follow the prompts for entering information:

/nas/sbin/server_user server_2 -add -md5 -passwd [DOMAIN\DOMAINUSER for msrpcuser]

Step 6 – Start the CEPA facility on the Data Mover. Use the following command:

server_cepp [DATA_MOVER_NAME] -service –start

Then verify the CEPA status using the following command:

server_cepp [DATA_MOVER_NAME] -service –status

After the cepp.config file has been configured, you can configure and enable monitoring with the Activity Monitor. See the Netwrix Activity Monitor Documentation for additional information.