Install & Configure Dell CEE
Dell CEE should be installed on a Windows or a Linux server. The Dell CEE software isn't a Netwrix product. Dell customers have a support account with Dell to access the download.
Remember, the latest version is the recommended version of Dell CEE.
Install the Dell CEE package on the Windows server where the Activity Monitor agent will be deployed (recommended) or on any other Windows or Linux server.
Step 1 – Obtain the latest CEE install package from Dell and any additional license required for this component. It is recommended to use the most current version.
Step 2 – Follow the instructions in the Dell Using the Common Event Enabler on Windows Platforms guide to install and configure the CEE. The installation will add two services to the machine:
- EMC Checker Service (Display Name: EMC CAVA)
- EMC CEE Monitor (Display Name: EMC CEE Monitor)
The latest version of .NET Framework and Dell CEE is recommended to use with the asynchronous bulk delivery (VCAPS) feature.
See the CEE Debug Logs section for information on troubleshooting issues related to Dell CEE.
After Dell CEE installation is complete, connect Data Movers to the Dell CEE Server.
Configure Dell Registry Key Settings
In some cases, install Dell CEE on a different Windows server than the one where the Activity Monitor activity agent is deployed. In those cases, manually set the Dell CEE registry key to forward events.
Step 1 – Open the Registry Editor (run regedit).

Step 2 – Navigate to following location:
HKEY_LOCAL_MACHINE\SOFTWARE\EMC\CEE\CEPP\AUDIT\Configuration
Step 3 – Right-click Enabled and select Modify. The Edit DWORD Value window opens.
Step 4 – In the Value data field, enter the value of 1. Click OK, and the Edit DWORD Value window closes.
Step 5 – Right-click EndPoint and select Modify. The Edit String window opens.
Step 6 – In the Value data field, enter the StealthAUDIT value with the IP Address for the Windows proxy server hosting the Activity Monitor activity agent. Use the following format:
StealthAUDIT@[IP ADDRESS]
Examples:
StealthAUDIT@192.168.30.15
Step 7 – Click OK. The Edit String window closes. Registry Editor can be closed.

Step 8 – Open Services (run services.msc). Start or Restart the EMC CEE Monitor service.
The Dell CEE registry key is now properly configured to forward event to the Activity Monitor activity agent.
Connect Data Movers to the Dell CEE Server
The cepp.conf file contains information that is necessary to connect the Data Movers to the Dell
CEE server. An administrator must create a configuration file which contains at least one event, one
pool, and one server. All other parameters are optional. The cepp.conf file resides on the Data
Mover.
Step 1 – Log into the Dell Celerra or VNX server with an administrator account. The administrative account should have a $ character in the terminal.
Don't use a # charter.
Step 2 – Create or retrieve the cepp.conf file.
If there isn't a cepp.conf file on the Data Movers, use a text editor to create a new blank
file in the home directory named cepp.conf. The following is an example command if using the text
editor 'vi' to create a new blank file:
$ vi cepp.conf
If a
cepp.conffile already exists, retrieve it from the Data Movers for modification with the following command:
$ server_file [DATA_MOVER_NAME] -get cepp.conf cepp.conf
Step 3 – Configure the cepp.conf file. For information on the cepp.conf file, see the Dell
Using the Common Event Enabler for Windows Platforms
guide instructions on how to add parameters or edit the values or existing parameters.
Add the information to the file on one line or separate lines by using a space
and a """ at the end of each line, except for the last line and the lines that contain global
options: cifsserver, surveytime, ft, and msrpcuser.
Set the following parameters in the cepp.conf file for the Activity Monitor:
-
pool name=- Assign the name of the configuration container. This container is composed of the servers IP Address or FQDN where the Dell CEE is installed and where the list of events to be monitored is located. Name it as desired, but it must function as a pool name.
-
servers=- This should equal the IP Address or FQDN of the Windows server where the Dell CEE is installed. If several servers are specified, separate them with the vertical bar (|) or a colon (:).
-
postevents=- Include the following events (separated with the vertical bar):
CloseModified|CloseUnmodified|CreateDir|CreateFile|DeleteDir|DeleteFile|RenameDir|RenameFile|SetAclDir|SetAclFile - To monitor "Directory Read/List" operations, append
OpenDirto the list.
- Include the following events (separated with the vertical bar):
-
msrpcuser=-
Specify the domain account that runs the Dell CEE Monitor and Dell CAVA services on the Windows server. This parameter ensures that events are sent only to the appropriate servers.
All unspecified parameters use the default setting. For most configurations, the default setting is sufficient.
Example cepp.conf file format:
-
msrpcuser=[DOMAIN\DOMAINUSER]
pool name=[POOL_NAME] \
*servers=[IP_ADDRESS1]|[IP_ADDRESS2]|... *
postevents=[EVENT1]|[EVENT2]|...
Example cepp.conf file format for the Activity Monitor:
msrpcuser=[DOMAIN\DOMAINUSER running CEE services]
pool name=[POOL_NAME for configuration container] \
*servers=[IP_ADDRESS where CEE is installed]|... *
postevents=[EVENT1]|[EVENT2]|...
Example of a completed cepp.conf file for the Activity Monitor:
msrpcuser=example\user1
pool name=pool \
*servers=192.168.30.15 *
postevents=CloseModified|CloseUnmodified|CreateDir|CreateFile|DeleteDir|DeleteFile|RenameDir|RenameFile|SetAclDir|SetAclFile
Step 4 – Move the cepp.conf file to the Data Movers root file system. Run the following
command:
$ server_file [DATA_MOVER_NAME]-put cepp.conf cepp.conf
Each Data Mover which runs Celerra Event Publishing Agent (CEPA) must have a cepp.conf
file, but each configuration file can specify different events.
Step 5 – (Perform this step only if using the msrpcuser parameter) Register the MSRPC user
(see Step 3 for additional information on this parameter). Before starting CEPA for the first time,
the administrator must issue the following command from the Control Station and follow the prompts
for entering information:
/nas/sbin/server_user server_2 -add -md5 -passwd [DOMAIN\DOMAINUSER for msrpcuser]
Step 6 – Start the CEPA facility on the Data Mover. Use the following command:
server_cepp [DATA_MOVER_NAME] -service –start
Then verify the CEPA status using the following command:
server_cepp [DATA_MOVER_NAME] -service –status
After the cepp.config file has been configured, you can configure and enable monitoring with
the Activity Monitor. See the
Netwrix Activity Monitor Documentation
for additional information.