Error: Failed to Copy Remote Distributed Modules
Symptoms
Both of the following symptoms are present in your Netwrix Auditor Event Log Manager (ELM) environment:
- The Health Log prompts the following error message:
Failed to copy remote distributed modules.
Error details: The process cannot access the file because it is being used by another process.
- ELM is set to audit both a domain OU and the servers within that OU by IP address.
Cause
ELM audits the same server twice. This causes duplicates of the audit logs in the Netwrix Auditor ELM monitoring plan.
Resolution
Refer to one of the following options to resolve the issue:
-
Review the list of monitored computers. Remove the IP ranges and only audit OUs.
-
Review the list of monitored computers. Remove the OU and only audit target IP address ranges.