Symptom

The following error is indicated in your Health Log for a File Servers monitoring plan:

Event ID: 6141 
Description: Monitoring plan: %monitoring_plan_name%.
Item: %item_name%.

Could not locate the end of the event log for '%item_name%'. The event log might have been overwritten.

Causes

  1. The maximum log size of the target event log is configured incorrectly.
  2. Insufficient hardware resources of your Netwrix Auditor server affect the data collection process.
  3. Network traffic compression option is disabled.
  4. Event log settings are not propagated in the corresponding registry key − the settings are reverted after each edit.

Resolutions

Cause #1 − Incorrectly configured maximum log size

Review retention settings for the target logs − refer to the following article for additional information: https://docs.netwrix.com/docs/auditor/10_8 Server − Adjusting Event Log Size and Retention Settings · v10.6).

Cause #2 −Insufficient hardware resources

Review the hardware resources of your Netwrix Auditor server − refer to the following article for for additional information on sample deployment scenarios depending on the enivornment size: https://docs.netwrix.com/docs/auditor/10_8 − Sample Deployment Scenarios · v10.6).

Cause #3 − Network traffic compression option is disabled

Enable the network traffic compression option − refer to the following article for additional information: https://docs.netwrix.com/docs/auditor/10_8 (Netwrix Auditor Operations and Health − Network Traffic Compression · v10.6).

Cause #4 − Settings are reverted

Specify the maximum log size and action settings for the affected event log:

  1. In the target server, open Registry Editor and navigate to HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\EventLog\.
  2. Select the subkey for the affected event log.
  3. Review the AutoBackupLogFiles and Retention values of the subkey − modify both values to state 0. Right-click a value, select Modify, edit the Value data field to state 0, and click OK to save changes. Repeat these actions for the second value.