Object Reference Not Set to Instance of Object in Inactive User Tracker Health Log
Symptom
The following error is prompted in Netwrix Auditor Health Log for your Inactive User Tracker monitoring plan:
Source: Active Directory Inactive Users Audit Service
Event ID: 2002
Computer: %computer_name%
Description: Monitoring plan: %Inactive_User_Tracker_monitoring_plan%
The following error has occurred while processing '%computer_name%':
An error occurred: Object reference not set to an instance of an object.
Cause
The data collection account used does not have sufficient permissions to collect data.
Resolution
Configure the permissions for the data collection account used in Inactive User Tracker. For additional information, refer to the following article: Monitoring Plans — Data Collecting Account.
Related articles
- Monitoring Plans — Data Collecting Account ⸱ 10.6