Symptoms​

The following symptoms are present in your Netwrix Auditor environment:

  • After upgrading Auditor to v10.7.13707, the Netwrix Auditor Data Collection Service (NwDataCollectionCoreSvc) stops or crashes regularly.

  • Auditor prompts the following error in the Health Log for previously unaffected monitoring plans:

    Event ID: 6117
    Monitoring plan: %Monitoring_Plan_name%
    Netwrix Auditor was unable to send Activity Summary: Failed to process a request because the target server is unreachable.

Cause​

An issue fixed in Auditor v10.7.13710 and later.

Resolution​

Upgrade your Auditor instance to v10.7.13710 or later. Download the executable in My Products · Netwrix.